Sign inCreate account
Sign inCreate account

Fluke 773. Process Clamp Meter

Ahorre tiempo SIN interrumpir el circuito en las mediciones de las señales de 4 a 20 mA.

Si necesita más tiempo en su ajetreado día preste atención a las pinzas amperimétricas para medir miliamperios Fluke 773. Están diseñadas para ahorrarle tiempo y dinero eliminando las actividades que consumen tiempo. Ahora, puede solucionar y reparar los circuitos de 4 a 20 mA sin interrumpirlos ni parar el sistema.

In stock at Edimar · Available for immediate dispatch

1.606,00 € excluding VAT - 1.943,26 € including VAT

✓ This product supports 3% welcome discount. Conditions

Quantity
    EAN: 0095969475822 SKU FLK 773 Categories , , Brand:
    MPN: Fluke 773
    Fluke

    Share this product:

    Description

    Fluke 773 process mA clamp meter

    Ahorre tiempo SIN interrumpir el circuito en las mediciones de las señales de 4 a 20 mA. Si pierde tiempo:
    • Removing cables and interrupting circuits to take mA measurements.
    • Calling the control centre to isolate circuits.
    • Checking analog inputs and outputs on a console.
    • Troubleshooting devices with mA input and output.
    • Repairing intermittent or erratic 4 to 20 mA circuits.
    • Returning to the store for more instruments.
    Si necesita más tiempo en su ajetreado día preste atención a las pinzas amperimétricas para medir miliamperios Fluke 773. Están diseñadas para ahorrarle tiempo y dinero eliminando las actividades que consumen tiempo. Ahora, puede solucionar y reparar los circuitos de 4 a 20 mA sin interrumpirlos ni parar el sistema. A continuación encontrará algunas maneras específicas en las que las pinzas amperimétricas Fluke 773 le ayudarán:

    Features of milliamps clamp meters

    Measurement of PLC mA signals and analog input/output signals of control systems without interrupting circuits.

    • Measures low-range DC currents.
    • Relates process indication to actual physical values.

    Measurement of transmitter output signals without interrupting the circuit.

    • Maintains and troubleshoots process and automation equipment without opening circuits.
    • Does not interrupt processes.

    Detachable clamp with extension cable.

    • Measurements in hard-to-reach areas.
    • Allows measurements in challenging situations.

    Measurement spotlight.

    • Illuminates hard-to-see cables in poorly lit areas.
    • Makes the measurement process easier and faster.

    Non-contact measurement up to a 99,9 mA range.

    • Wide measurement range.
    • Measures signals from 10 to 50 mA in older control systems.

    Auto power off.

    • Automatic switch-off of the light and backlighting after 15 minutes and 2 minutes respectively.
    • Increases battery life.

    Main features:

    The Fluke 773 mA clamp meter includes:
    • Best-in-class accuracy: 0,2 %.
    • Resolution and sensitivity of 0,01 mA.
    • Medición de señales 4 a 20 mA sin «interrumpir el circuito».
    • Measurement of mA signals for analogue I/O of the control system and PLC.
    • Dual display with backlighting, showing mA measurement and percentage of the range from 4 to 20 mA.
    • Light to illuminate cables in poorly lit areas.
    • Detachable clamp with extension cable for measurements in narrow spaces.
    • Measurement of signals from 10 to 50 mA in older control systems using the 99,9 mA range.
    • Automatic switching of output from 4 to 20 mA for remote testing.
    • Energy-saving features, automatic shutdown, backlight off to extend battery life.
    • Hold function captures and displays continuously changing measurements.
    • Measurement of signals from 4 to 20 mA with internal circuit measurement.
    • Simultaneous mA measurement in the circuit with loop power of 24 V for transmitter connection and testing.
    • Generation of signals from 4 to 20 mA for I/O or I/P testing of control systems.
    • Ramp or increment mA output of 25 %.
    • Automatic switching of output from 4 to 20 mA for remote testing.
    • DC voltage measurement to verify power supplies of 24 V or analog I/O voltage signals.
    • DC voltage generation for testing input devices accepting signals from 1 to 5 volts or from 0 to 10 volts.
    • Graduated mA output provides a continuous mA signal corresponding to the 4 to 20 mA signal measured with the clamp meter (mA).
    • Allows recording of milliamps signals on an independent recording device without interrupting the loop.
    • The mA output signal enables a digital multimeter with data logging or any other device to record the 4 to 20 mA signal without interrupting the circuit.
    • mA output/input: simultaneous measurement of the mA signal with the clamp and generation of an mA signal.
    • Application of an mA input signal to a device and measurement of the 4-20 mA output on devices such as valves or mA isolators.
    • Output voltage ramp or linear increment of a 25 %.
    • Automatic switching of output voltage for remote testing.
    • Fluke 773 process clamp meter.
    EDIMAR ADVICE

    How can we help you?

    Consult us about availability, quantities or technical product details.