  • Quickly and accurately locate live and dead wires in walls, ceilings and floors.
  • The patented Smart Sensor™ technology locates and displays live wires on the colour screen.
  • Locate breaks, open circuits and short circuits and easily identify switches and fuses.
  • Safety category CAT IV 600 V.
  • Includes the AC clamp meter i400, which allows inducing a locating signal on the cable when access to bare conductors is not possible.
Check the lead time with Edimar.

Available on backorder

2.585,00 € excluding VAT - 3.127,85 € including VAT

Available on backorder

✓ This product supports 3% welcome discount. Conditions

Quantity
    EAN: 00195112044575 SKU 5353866 Categories , Brand:
    MPN: 5353866
    Fluke

    Share this product:

    Description

    Specifications: Fluke 2062 Pro advanced cable locator kit

    General

    Receiver 2062RTransmitter 2000TAC clamp meter i400
    Safety categoryCAT IV 600 VCAT IV 600 VCAT IV 600 V, CAT III 1000 V
    Operating voltage600 V CA/CC600 V CA/CC1000 V CA
    Operating frequencyWith voltage: 6,25 kHz
    Without voltage: 32,768 kHz
    With voltage/loop: 6,25 kHz
    Without voltage: 32,768 kHz
    N/A
    Signal indicationsNumeric display, bar graph and audible beepLED and audible beepN/A
    Response timeSmart Sensor: 500 ms
    Tip sensor (with/without voltage): 500 ms
    NCV: 500 ms
    Battery monitoring: 5 s
    Line voltage monitoring: 1 s
    Battery voltage monitoring: 5 s
    N/A
    Output signal current (typical)N/ACircuit with voltage:
    High mode: 60 mA rms
    Low mode: 30 mA rms
    Circuit without voltage:
    High mode: 110 mA rms
    Low mode: 40 mA rms
    Loop mode with test leads: 160 mA rms
    Loop mode with AC clamp meter i400: 385 mA rms
    N/A
    Output signal voltage (nominal)N/ACircuit with voltage:
    High mode: 14 W at 230 V CA/50 Hz, 3,33 kΩ at 230 VAC
    Low mode: 4,6 W at 230 V CA/50 Hz, 11,5 kΩ at 230 VAC
    Circuit without voltage:
    High mode: 31 V RMS, 140 Vp-p, 0,86 W at 1 kΩ load
    Low mode: 27,5 V RMS, 120 Vp-p, 0,1 W at 1 kΩ load
    Loop mode with test leads: 32 V RMS, 140 Vp-p, 0,87 W at 1 kΩ load
    Loop mode with AC clamp meter i400: 31 mV, 0,89 W at 1 Ω load
    N/A
    Detection distance (open air)Smart Sensor direction indication mode
    ≤15 cm (6”), 230 VAC, high mode, sensitivity level 2
    Tip sensor: With voltage
    Maximum open air distance: up to 6,1 m (20 feet)
    Localización exacta: aprox. 5 cm (1,97″)
    Tip sensor: Without voltage
    Maximum open air distance: up to 4,5 m (14,7 feet)
    Localización exacta: aprox. 5 cm (1,97″)
    NCV (40 Hz to 400 Hz):
    Maximum sensitivity: 90 V up to 2 m
    Minimum sensitivity: 600 V up to 1 cm
    N/AN/A
    Current rangeN/AN/A400 A
    Basic accuracyN/AN/A2% + 0,06 A (45 Hz to 400 Hz)

    Display

    Receiver 2062RTransmitter 2000TAC clamp meter i400
    Display sizeLCD 3,5″ (89 mm)LEDN/A
    Display dimensions (width x height)70 x 52 mm (2,76 x 2,07″)N/AN/A
    Display resolution480 pixels x 320 pixelsN/AN/A
    Display typeColour TFT LCDLEDN/A
    Display colour16 bitsOperating mode LED: red
    Battery status LED: green, yellow, red
    N/A
    BacklightYesN/AN/A

    Environmental

    Receiver 2062RTransmitter 2000TAC clamp meter i400
    Operating temperature−20 °C to 50 °C (−4 °F to 122 °F)−20 °C to 50 °C (−4 °F to 122 °F)−20 °C to 50 °C (−4 °F to 122 °F)
    Operating humidity45%: -20 °C to <10 °C or 40 °C to 50 °C
    (-4 °F to <50 °F or 104 °F to 122 °F)
    95% (non-condensing): 10 °C to <30 °C
    (50 °F to 86 °F)
    75%: 30 °C to <40 °C (86 °F to <104 °F)
    45%: -20 °C to <10 °C or 40 °C to 50 °C
    (-4 °F to <50 °F or 104 °F to 122 °F)
    95% (non-condensing): 10 °C to <30 °C
    (50 °F to 86 °F)
    75%: 30 °C to <40 °C (86 °F to <104 °F)
    10 °C to <30 °C (95 %: from 50 °F to <86 °F)
    From 30 °C to <40 °C (75 %: from 86 °F to <104 °F)
    From 40 °C to <50 °C (45 %: from 104 °F to <122 °F)
    Operating altitude2000 m (6561 feet)2000 m (6561 feet)2000 m (6561 feet)
    Transient protectionN/A8,00 kV (peaks of 1,2/50 μs)N/A
    Pollution degree222
    IP protectionIP 40IP 40IP 40
    Drop test1 m (3,28 feet)1 m (3,28 feet)1 m (3,28 feet)

    Mechanical

    Receiver 2062RTransmitter 2000TAC clamp meter i400
    Power supply4 AA batteries (alkaline)8 AA batteries (alkaline)N/A
    Consumption (typical)110 mAHigh/low mode: 70 mA
    Loop mode with clamp: 90 mA
    Consumption without transmission signal: 10 mA
    N/A
    Battery lifeApprox. 20 hHigh/low mode: approx. 25 h
    Loop mode: approx. 18 h
    N/A
    Low charge indicationYesYesN/A
    FuseN/A1,6 A, 700 V, fast acting, Ø 6 x 32 mm, breaking capacity 50 kAN/A
    Maximum conductor sizeN/AN/A32 mm (1,26″)
    Dimensions (L x W x H)Aprox. 277 x 112 x 65 mm (10,92 x 4,43 x 2,55″)Aprox. 183 x 93 x 50 mm (7,2 x 3,66 x 1,97″)Aprox. 150 x 70 x 30 mm (5,9 x 2,75 x 1,18″)
    WeightApprox. 0,544 kg (1,20 lb)Approx. 0,57 kg (1,25 lb)Approx. 0,114 kg (0,25 lb)

    Accessory and test cable kit 2000ACC

    • Includes:
      • 2 test cables of 1 m (red, black)
      • 1 test cable of 7 m (green)
      • 2 test probes (black)
      • 2 crocodile clips (red and black)
      • 2 flat socket adapters (red, black)
      • 2 round socket adapters (red, black)
    • Safety category: CAT IV 600 V (test cables), CAT II 1000 V (test probes), CAT IV 600 V (crocodile clips), CAT II 300 V (socket adapters)
    • Operating voltage and current: 600 V, 10 A max. (red and black cables), 600 V, 10 A max. (green cable), 1000 V, 8 A max. (test probe)
    • Water and dust protection: IP 20
    • Drop resistance: 1 m (3,28 feet)