Available on backorder
2.585,00 € excluding VAT - 3.127,85 € including VAT
Available on backorder
✓ This product supports 3% welcome discount. Conditions

Share this product:
| Receiver 2062R | Transmitter 2000T | AC clamp meter i400 | |
|---|---|---|---|
| Safety category | CAT IV 600 V | CAT IV 600 V | CAT IV 600 V, CAT III 1000 V |
| Operating voltage | 600 V CA/CC | 600 V CA/CC | 1000 V CA |
| Operating frequency | With voltage: 6,25 kHz Without voltage: 32,768 kHz | With voltage/loop: 6,25 kHz Without voltage: 32,768 kHz | N/A |
| Signal indications | Numeric display, bar graph and audible beep | LED and audible beep | N/A |
| Response time | Smart Sensor: 500 ms Tip sensor (with/without voltage): 500 ms NCV: 500 ms Battery monitoring: 5 s | Line voltage monitoring: 1 s Battery voltage monitoring: 5 s | N/A |
| Output signal current (typical) | N/A | Circuit with voltage: High mode: 60 mA rms Low mode: 30 mA rms Circuit without voltage: High mode: 110 mA rms Low mode: 40 mA rms Loop mode with test leads: 160 mA rms Loop mode with AC clamp meter i400: 385 mA rms | N/A |
| Output signal voltage (nominal) | N/A | Circuit with voltage: High mode: 14 W at 230 V CA/50 Hz, 3,33 kΩ at 230 VAC Low mode: 4,6 W at 230 V CA/50 Hz, 11,5 kΩ at 230 VAC Circuit without voltage: High mode: 31 V RMS, 140 Vp-p, 0,86 W at 1 kΩ load Low mode: 27,5 V RMS, 120 Vp-p, 0,1 W at 1 kΩ load Loop mode with test leads: 32 V RMS, 140 Vp-p, 0,87 W at 1 kΩ load Loop mode with AC clamp meter i400: 31 mV, 0,89 W at 1 Ω load | N/A |
| Detection distance (open air) | Smart Sensor direction indication mode ≤15 cm (6”), 230 VAC, high mode, sensitivity level 2 Tip sensor: With voltage Maximum open air distance: up to 6,1 m (20 feet) Localización exacta: aprox. 5 cm (1,97″) Tip sensor: Without voltage Maximum open air distance: up to 4,5 m (14,7 feet) Localización exacta: aprox. 5 cm (1,97″) NCV (40 Hz to 400 Hz): Maximum sensitivity: 90 V up to 2 m Minimum sensitivity: 600 V up to 1 cm | N/A | N/A |
| Current range | N/A | N/A | 400 A |
| Basic accuracy | N/A | N/A | 2% + 0,06 A (45 Hz to 400 Hz) |
| Receiver 2062R | Transmitter 2000T | AC clamp meter i400 | |
|---|---|---|---|
| Display size | LCD 3,5″ (89 mm) | LED | N/A |
| Display dimensions (width x height) | 70 x 52 mm (2,76 x 2,07″) | N/A | N/A |
| Display resolution | 480 pixels x 320 pixels | N/A | N/A |
| Display type | Colour TFT LCD | LED | N/A |
| Display colour | 16 bits | Operating mode LED: red Battery status LED: green, yellow, red | N/A |
| Backlight | Yes | N/A | N/A |
| Receiver 2062R | Transmitter 2000T | AC clamp meter i400 | |
|---|---|---|---|
| Operating temperature | −20 °C to 50 °C (−4 °F to 122 °F) | −20 °C to 50 °C (−4 °F to 122 °F) | −20 °C to 50 °C (−4 °F to 122 °F) |
| Operating humidity | 45%: -20 °C to <10 °C or 40 °C to 50 °C (-4 °F to <50 °F or 104 °F to 122 °F) 95% (non-condensing): 10 °C to <30 °C (50 °F to 86 °F) 75%: 30 °C to <40 °C (86 °F to <104 °F) | 45%: -20 °C to <10 °C or 40 °C to 50 °C (-4 °F to <50 °F or 104 °F to 122 °F) 95% (non-condensing): 10 °C to <30 °C (50 °F to 86 °F) 75%: 30 °C to <40 °C (86 °F to <104 °F) | 10 °C to <30 °C (95 %: from 50 °F to <86 °F) From 30 °C to <40 °C (75 %: from 86 °F to <104 °F) From 40 °C to <50 °C (45 %: from 104 °F to <122 °F) |
| Operating altitude | 2000 m (6561 feet) | 2000 m (6561 feet) | 2000 m (6561 feet) |
| Transient protection | N/A | 8,00 kV (peaks of 1,2/50 μs) | N/A |
| Pollution degree | 2 | 2 | 2 |
| IP protection | IP 40 | IP 40 | IP 40 |
| Drop test | 1 m (3,28 feet) | 1 m (3,28 feet) | 1 m (3,28 feet) |
| Receiver 2062R | Transmitter 2000T | AC clamp meter i400 | |
|---|---|---|---|
| Power supply | 4 AA batteries (alkaline) | 8 AA batteries (alkaline) | N/A |
| Consumption (typical) | 110 mA | High/low mode: 70 mA Loop mode with clamp: 90 mA Consumption without transmission signal: 10 mA | N/A |
| Battery life | Approx. 20 h | High/low mode: approx. 25 h Loop mode: approx. 18 h | N/A |
| Low charge indication | Yes | Yes | N/A |
| Fuse | N/A | 1,6 A, 700 V, fast acting, Ø 6 x 32 mm, breaking capacity 50 kA | N/A |
| Maximum conductor size | N/A | N/A | 32 mm (1,26″) |
| Dimensions (L x W x H) | Aprox. 277 x 112 x 65 mm (10,92 x 4,43 x 2,55″) | Aprox. 183 x 93 x 50 mm (7,2 x 3,66 x 1,97″) | Aprox. 150 x 70 x 30 mm (5,9 x 2,75 x 1,18″) |
| Weight | Approx. 0,544 kg (1,20 lb) | Approx. 0,57 kg (1,25 lb) | Approx. 0,114 kg (0,25 lb) |
Consult us about availability, quantities or technical product details.