{"id":2129,"date":"2024-09-24T12:07:33","date_gmt":"2024-09-24T12:07:33","guid":{"rendered":"https:\/\/electronicaedimar.com\/producto\/fluke-2062\/"},"modified":"2026-11-04T09:01:19","modified_gmt":"2026-11-04T07:01:19","slug":"fluke-2062","status":"publish","type":"product","link":"https:\/\/electronicaedimar.com\/en\/product\/fluke-2062\/","title":{"rendered":"Fluke 2062"},"content":{"rendered":"<h1>Specifications: Fluke 2062 Pro advanced cable locator kit<\/h1>\n<h2>General<\/h2>\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th>Receiver 2062R<\/th>\n<th>Transmitter 2000T<\/th>\n<th>AC clamp meter i400<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Safety category<\/td>\n<td>CAT IV 600 V<\/td>\n<td>CAT IV 600 V<\/td>\n<td>CAT IV 600 V, CAT III 1000 V<\/td>\n<\/tr>\n<tr>\n<td>Operating voltage<\/td>\n<td>600 V CA\/CC<\/td>\n<td>600 V CA\/CC<\/td>\n<td>1000 V CA<\/td>\n<\/tr>\n<tr>\n<td>Operating frequency<\/td>\n<td>With voltage: 6,25 kHz<br \/>Without voltage: 32,768 kHz<\/td>\n<td>With voltage\/loop: 6,25 kHz<br \/>Without voltage: 32,768 kHz<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Signal indications<\/td>\n<td>Numeric display, bar graph and audible beep<\/td>\n<td>LED and audible beep<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Response time<\/td>\n<td>Smart Sensor: 500 ms<br \/>Tip sensor (with\/without voltage): 500 ms<br \/>NCV: 500 ms<br \/>Battery monitoring: 5 s<\/td>\n<td>Line voltage monitoring: 1 s<br \/>Battery voltage monitoring: 5 s<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Output signal current (typical)<\/td>\n<td>N\/A<\/td>\n<td>Circuit with voltage:<br \/>High mode: 60 mA rms<br \/>Low mode: 30 mA rms<br \/>Circuit without voltage:<br \/>High mode: 110 mA rms<br \/>Low mode: 40 mA rms<br \/>Loop mode with test leads: 160 mA rms<br \/>Loop mode with AC clamp meter i400: 385 mA rms<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Output signal voltage (nominal)<\/td>\n<td>N\/A<\/td>\n<td>Circuit with voltage:<br \/>High mode: 14 W at 230 V CA\/50 Hz, 3,33 k\u03a9 at 230 VAC<br \/>Low mode: 4,6 W at 230 V CA\/50 Hz, 11,5 k\u03a9 at 230 VAC<br \/>Circuit without voltage:<br \/>High mode: 31 V RMS, 140 Vp-p, 0,86 W at 1 k\u03a9 load<br \/>Low mode: 27,5 V RMS, 120 Vp-p, 0,1 W at 1 k\u03a9 load<br \/>Loop mode with test leads: 32 V RMS, 140 Vp-p, 0,87 W at 1 k\u03a9 load<br \/>Loop mode with AC clamp meter i400: 31 mV, 0,89 W at 1 \u03a9 load<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Detection distance (open air)<\/td>\n<td>Smart Sensor direction indication mode<br \/>\u226415 cm (6\u201d), 230 VAC, high mode, sensitivity level 2<br \/>Tip sensor: With voltage<br \/>Maximum open air distance: up to 6,1 m (20 feet)<br \/>Localizaci\u00f3n exacta: aprox. 5 cm (1,97&#8243;)<br \/>Tip sensor: Without voltage<br \/>Maximum open air distance: up to 4,5 m (14,7 feet)<br \/>Localizaci\u00f3n exacta: aprox. 5 cm (1,97&#8243;)<br \/>NCV (40 Hz to 400 Hz):<br \/>Maximum sensitivity: 90 V up to 2 m<br \/>Minimum sensitivity: 600 V up to 1 cm<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Current range<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>400 A<\/td>\n<\/tr>\n<tr>\n<td>Basic accuracy<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>2% + 0,06 A (45 Hz to 400 Hz)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Display<\/h2>\n<table border=\"1\" cellpadding=\"10\" cellspacing=\"0\">\n<thead>\n<tr>\n<th><\/th>\n<th>Receiver 2062R<\/th>\n<th>Transmitter 2000T<\/th>\n<th>AC clamp meter i400<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Display size<\/td>\n<td>LCD 3,5&#8243; (89 mm)<\/td>\n<td>LED<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Display dimensions (width x height)<\/td>\n<td>70 x 52 mm (2,76 x 2,07&#8243;)<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>480 pixels x 320 pixels<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Display type<\/td>\n<td>Colour TFT LCD<\/td>\n<td>LED<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Display colour<\/td>\n<td>16 bits<\/td>\n<td>Operating mode LED: red<br \/>Battery status LED: green, yellow, red<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Backlight<\/td>\n<td>Yes<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Environmental<\/h2>\n<table border=\"1\" cellpadding=\"10\" cellspacing=\"0\">\n<thead>\n<tr>\n<th><\/th>\n<th>Receiver 2062R<\/th>\n<th>Transmitter 2000T<\/th>\n<th>AC clamp meter i400<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Operating temperature<\/td>\n<td>\u221220 \u00b0C to 50 \u00b0C (\u22124 \u00b0F to 122 \u00b0F)<\/td>\n<td>\u221220 \u00b0C to 50 \u00b0C (\u22124 \u00b0F to 122 \u00b0F)<\/td>\n<td>\u221220 \u00b0C to 50 \u00b0C (\u22124 \u00b0F to 122 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Operating humidity<\/td>\n<td>45%: -20 \u00b0C to &lt;10 \u00b0C or 40 \u00b0C to 50 \u00b0C<br \/>(-4 \u00b0F to &lt;50 \u00b0F or 104 \u00b0F to 122 \u00b0F)<br \/>95% (non-condensing): 10 \u00b0C to &lt;30 \u00b0C<br \/>(50 \u00b0F to 86 \u00b0F)<br \/>75%: 30 \u00b0C to &lt;40 \u00b0C (86 \u00b0F to &lt;104 \u00b0F)<\/td>\n<td>45%: -20 \u00b0C to &lt;10 \u00b0C or 40 \u00b0C to 50 \u00b0C<br \/>(-4 \u00b0F to &lt;50 \u00b0F or 104 \u00b0F to 122 \u00b0F)<br \/>95% (non-condensing): 10 \u00b0C to &lt;30 \u00b0C<br \/>(50 \u00b0F to 86 \u00b0F)<br \/>75%: 30 \u00b0C to &lt;40 \u00b0C (86 \u00b0F to &lt;104 \u00b0F)<\/td>\n<td>10 \u00b0C to &lt;30 \u00b0C (95 %: from 50 \u00b0F to &lt;86 \u00b0F)<br \/>From 30 \u00b0C to &lt;40 \u00b0C (75 %: from 86 \u00b0F to &lt;104 \u00b0F)<br \/>From 40 \u00b0C to &lt;50 \u00b0C (45 %: from 104 \u00b0F to &lt;122 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Operating altitude<\/td>\n<td>2000 m (6561 feet)<\/td>\n<td>2000 m (6561 feet)<\/td>\n<td>2000 m (6561 feet)<\/td>\n<\/tr>\n<tr>\n<td>Transient protection<\/td>\n<td>N\/A<\/td>\n<td>8,00 kV (peaks of 1,2\/50 \u03bcs)<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Pollution degree<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>IP protection<\/td>\n<td>IP 40<\/td>\n<td>IP 40<\/td>\n<td>IP 40<\/td>\n<\/tr>\n<tr>\n<td>Drop test<\/td>\n<td>1 m (3,28 feet)<\/td>\n<td>1 m (3,28 feet)<\/td>\n<td>1 m (3,28 feet)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical<\/h2>\n<table border=\"1\" cellpadding=\"10\" cellspacing=\"0\">\n<thead>\n<tr>\n<th><\/th>\n<th>Receiver 2062R<\/th>\n<th>Transmitter 2000T<\/th>\n<th>AC clamp meter i400<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Power supply<\/td>\n<td>4 AA batteries (alkaline)<\/td>\n<td>8 AA batteries (alkaline)<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Consumption (typical)<\/td>\n<td>110 mA<\/td>\n<td>High\/low mode: 70 mA<br \/>Loop mode with clamp: 90 mA<br \/>Consumption without transmission signal: 10 mA<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Battery life<\/td>\n<td>Approx. 20 h<\/td>\n<td>High\/low mode: approx. 25 h<br \/>Loop mode: approx. 18 h<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Low charge indication<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Fuse<\/td>\n<td>N\/A<\/td>\n<td>1,6 A, 700 V, fast acting, \u00d8 6 x 32 mm, breaking capacity 50 kA<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Maximum conductor size<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>32 mm (1,26&#8243;)<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (L x W x H)<\/td>\n<td>Aprox. 277 x 112 x 65 mm (10,92 x 4,43 x 2,55&#8243;)<\/td>\n<td>Aprox. 183 x 93 x 50 mm (7,2 x 3,66 x 1,97&#8243;)<\/td>\n<td>Aprox. 150 x 70 x 30 mm (5,9 x 2,75 x 1,18&#8243;)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 0,544 kg (1,20 lb)<\/td>\n<td>Approx. 0,57 kg (1,25 lb)<\/td>\n<td>Approx. 0,114 kg (0,25 lb)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Accessory and test cable kit 2000ACC<\/h2>\n<ul>\n<li>Includes:\n<ul>\n<li>2 test cables of 1 m (red, black)<\/li>\n<li>1 test cable of 7 m (green)<\/li>\n<li>2 test probes (black)<\/li>\n<li>2 crocodile clips (red and black)<\/li>\n<li>2 flat socket adapters (red, black)<\/li>\n<li>2 round socket adapters (red, black)<\/li>\n<\/ul>\n<\/li>\n<li>Safety category: CAT IV 600 V (test cables), CAT II 1000 V (test probes), CAT IV 600 V (crocodile clips), CAT II 300 V (socket adapters)<\/li>\n<li>Operating voltage and current: 600 V, 10 A max. (red and black cables), 600 V, 10 A max. (green cable), 1000 V, 8 A max. (test probe)<\/li>\n<li>Water and dust protection: IP 20<\/li>\n<li>Drop resistance: 1 m (3,28 feet)<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<h1>Main features<\/h1>\n<ul>\n<li>Quickly and accurately locate live and dead wires in walls, ceilings and floors.<\/li>\n<li>The patented Smart Sensor\u2122 technology locates and displays live wires on the colour screen.<\/li>\n<li>Locate breaks, open circuits and short circuits and easily identify switches and fuses.<\/li>\n<li>Safety category CAT IV 600 V.<\/li>\n<li>Includes the AC clamp meter i400, which allows inducing a locating signal on the cable when access to bare conductors is not possible.<\/li>\n<\/ul>","protected":false},"featured_media":2127,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_joinchat":[]},"product_brand":[139],"product_cat":[35,80],"product_tag":[],"class_list":["post-2129","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke","product_cat-instrumentacion-electronica","product_cat-localizador-de-cables-instrumentacion-electronica","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product\/2129","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/comments?post=2129"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/media\/2127"}],"wp:attachment":[{"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/media?parent=2129"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product_brand?post=2129"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product_cat?post=2129"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product_tag?post=2129"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}