{"id":2116,"date":"2024-09-20T15:52:59","date_gmt":"2024-09-20T15:52:59","guid":{"rendered":"https:\/\/electronicaedimar.com\/producto\/fluke-t6-1000pro-eu\/"},"modified":"2026-11-04T09:01:19","modified_gmt":"2026-11-04T07:01:19","slug":"fluke-t6-1000pro-eu","status":"publish","type":"product","link":"https:\/\/electronicaedimar.com\/en\/product\/fluke-t6-1000pro-eu\/","title":{"rendered":"Fluke T6-1000PRO\/EU"},"content":{"rendered":"<h1>Especificaciones: Comprobador el\u00e9ctrico Fluke T6-1000 PRO<\/h1>\n<h2>Funci\u00f3n<\/h2>\n<ul>\n<li>Tensi\u00f3n CA FieldSense\n<ul>\n<li>Requiere cables de prueba: No<\/li>\n<li>Rango: 1000 V<\/li>\n<li>Resoluci\u00f3n: 1 V<\/li>\n<li>Precisi\u00f3n: \u00b1(3% + 3 cuentas) 45 Hz &#8211; 66 Hz<sup>[1]<\/sup> <sup>[3]<\/sup><\/li>\n<\/ul>\n<\/li>\n<li>Corriente CA FieldSense\n<ul>\n<li>Requiere cables de prueba: No<\/li>\n<li>Rango: 200,0 A<\/li>\n<li>Resoluci\u00f3n: 0,1 A<\/li>\n<li>Precisi\u00f3n: \u00b1(3% + 3 cuentas) 45 Hz &#8211; 66 Hz<\/li>\n<\/ul>\n<\/li>\n<li>Frecuencia FieldSense (Hz)\n<ul>\n<li>Requiere cables de prueba: No<\/li>\n<li>Rango: 45 Hz \u2013 66 Hz<\/li>\n<li>Resoluci\u00f3n: 1 Hz<\/li>\n<li>Precisi\u00f3n: \u00b1(1% + 2 cuentas)<\/li>\n<\/ul>\n<\/li>\n<li>Tensi\u00f3n CA\n<ul>\n<li>Requiere cables de prueba: S\u00ed<\/li>\n<li>Rango: 1000 V<\/li>\n<li>Resoluci\u00f3n: 1 V<\/li>\n<li>Precisi\u00f3n: \u00b1(1,5% + 2 cuentas) 45 Hz &#8211; 66 Hz<\/li>\n<\/ul>\n<\/li>\n<li>Tensi\u00f3n CC\n<ul>\n<li>Requiere cables de prueba: S\u00ed<\/li>\n<li>Rango: 1000 V<\/li>\n<li>Resoluci\u00f3n: 1 V<\/li>\n<li>Precisi\u00f3n: \u00b1(1% + 2 cuentas)<\/li>\n<\/ul>\n<\/li>\n<li>Resistencia\n<ul>\n<li>Requiere cables de prueba (todos los rangos): S\u00ed<\/li>\n<li>Rango: 2000 \u2126, 20,00 k\u2126, 100,0 k\u2126<\/li>\n<li>Resoluci\u00f3n: 1 \u2126, 0,01 k\u2126, 0,1 k\u2126<\/li>\n<li>Precisi\u00f3n (todos los rangos): \u00b1(1% + 2 cuentas)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>Precisi\u00f3n[1]: \u00b1 ( [% de la lectura] + [n\u00famero de d\u00edgitos menos significativos]). La precisi\u00f3n se especifica durante 1 a\u00f1o despu\u00e9s de la calibraci\u00f3n, a temperaturas de funcionamiento de 18 \u00b0C a 28 \u00b0C, con una humedad relativa de hasta el 90%. Las medidas de CA se acoplan para CA y responden al verdadero valor eficaz.<\/p>\n<p>Precisi\u00f3n[2]: FieldSense especificado de 16 V a 1000 V.<\/p>\n<h2>Especificaciones generales<\/h2>\n<ul>\n<li>Soluciones: Ciclo de calibraci\u00f3n de 1 a\u00f1o<\/li>\n<li>Dimensiones: 61 mm x 259 mm x 43 mm<\/li>\n<li>Peso: 0,35 kg (0,78 lb)<\/li>\n<li>Apertura de la mordaza: 17,8 mm (0,7&#8243;)<\/li>\n<li>Temperatura:\n<ul>\n<li>Funcionamiento: -10 \u00b0C a +50 \u00b0C (14 \u00b0F a 122 \u00b0F)<\/li>\n<li>Almacenamiento: -30 \u00b0C a +60 \u00b0C (-22 \u00b0F a +140 \u00b0F)<\/li>\n<\/ul>\n<\/li>\n<li>Altitud:\n<ul>\n<li>Funcionamiento: 2000 m (6562 pies)<\/li>\n<li>Almacenamiento: 10.000 m (32.808 pies)<\/li>\n<\/ul>\n<\/li>\n<li>Humedad relativa:\n<ul>\n<li>0% a 90%, 5 \u00b0C a 30 \u00b0C (41 \u00b0F a 86 \u00b0F)<\/li>\n<li>0% a 75%, 30 \u00b0C a 40 \u00b0C (86 \u00b0F a 104 \u00b0F)<\/li>\n<li>0% a 45%, 40 \u00b0C a 50 \u00b0C (104 \u00b0F a 122 \u00b0F)<\/li>\n<\/ul>\n<\/li>\n<li>Bater\u00eda:\n<ul>\n<li>Tipo: 2 pilas AA (IEC LR6)<\/li>\n<li>Autonom\u00eda: 360 h de uso continuo, normalmente 200 h con funci\u00f3n FieldSense<\/li>\n<\/ul>\n<\/li>\n<li>Coeficiente de temperatura: 0,1 X (precisi\u00f3n especificada) \/ \u00b0C para &lt;18 \u00b0C o &gt;28 \u00b0C (&lt;64,4 \u00b0F o &gt;82,4 \u00b0F)<\/li>\n<\/ul>\n<h2>Seguridad<\/h2>\n<ul>\n<li>General:\n<ul>\n<li>Medidas de T6-1000 PRO: IEC 61010-1: Grado de contaminaci\u00f3n 2<\/li>\n<\/ul>\n<\/li>\n<li>IEC 61010-2-032: CAT IV 600 V\/CAT III 1000 V<\/li>\n<li>Compatibilidad electromagn\u00e9tica: IEC\/EN 61326-1: Port\u00e1til<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<h1>Main features<\/h1>\n<ul>\n<li>Save time by viewing voltage and current measurements simultaneously.<\/li>\n<li>Visual Continuity\u2122: the display automatically lights green to indicate continuity, very useful when there is too much noise to hear the beep.<\/li>\n<li>FieldSense\u2122: allows you to measure AC voltage, current and frequency without making electrical contact with the voltage.<\/li>\n<\/ul>","protected":false},"featured_media":6752,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_joinchat":[]},"product_brand":[139],"product_cat":[35,74],"product_tag":[],"class_list":["post-2116","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke","product_cat-instrumentacion-electronica","product_cat-comprobadores-electricos","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product\/2116","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/comments?post=2116"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/media\/6752"}],"wp:attachment":[{"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/media?parent=2116"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product_brand?post=2116"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product_cat?post=2116"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electronicaedimar.com\/en\/wp-json\/wp\/v2\/product_tag?post=2116"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}